Dental foundation training is the year when clinical knowledge meets the reality of everyday dentistry. Suddenly, treatment plans have deadlines, patients have expectations, materials behave differently outside textbooks, and a dental laboratory needs more information than “please make crown.” Learning how to work effectively with a dental laboratory is therefore not an administrative detail. It is a clinical skill. A clear prescription, accurate records and timely communication help the technician produce what you intended, reduce avoidable appointments and make outcomes more predictable. This guide explains how DFT dentists can build a productive relationship with their laboratory, avoid common problems and get better results for their patients. Your laboratory is part of the clinical team
A dental laboratory does not simply manufacture an item after the clinical work has finished. The restoration or appliance is the result of a shared workflow involving the dentist, patient, nurse and technician. The dentist controls the diagnosis, treatment plan, preparation, records and prescription. The laboratory interprets that information and converts it into a physical restoration or appliance. If information is incomplete, inaccurate or contradictory, the technician cannot safely compensate by guessing. This is one of the most useful lessons to learn during foundation training: the quality of the laboratory work can only be judged properly alongside the quality of the clinical information supplied. A good technician can identify risks, suggest solutions and prevent problems. They cannot recreate anatomy that is missing from an impression, determine an unknown occlusal relationship or choose a clinical design that has not been prescribed. Start by understanding what the laboratory needs Different restorations require different records, but the basic principle is consistent. The laboratory needs enough accurate information to understand:
These details should agree with one another. If the written prescription requests one shade while a photograph or scan note shows another, the laboratory has to stop and clarify the discrepancy. Before sending a case, ask yourself a simple question: if I were the technician receiving this work with no access to the patient, would I know exactly what I was expected to make? That short check prevents a surprising number of delays. Write a prescription that removes uncertainty “Make denture,” “crown to match” and “please do your best” are not adequate laboratory instructions. They transfer unanswered clinical decisions to someone who has not examined the patient. A strong prescription should be concise but specific. For a crown, this may include the tooth, restoration type, material, shade, stump shade where relevant, surface characteristics, contact requirements and any important occlusal considerations. For removable prosthetics, the prescription may need to cover the appliance type, teeth to be replaced, design, clasps, support, tooth shade and mould, bite information, requested stage and any existing appliance that should be copied or considered. Detailed does not mean unnecessarily long. The objective is to communicate the decisions that affect manufacture and remove ambiguity. If you are unsure about the most suitable material or design, speak to the laboratory before completing the prescription. Asking for technical input is good case management. It is different from leaving the decision unspecified and hoping the technician interprets your intention. Do not treat the impression as a routine formality An impression is the laboratory’s working representation of the patient. If the critical anatomy is absent, distorted or obscured, the technician cannot reliably manufacture the intended appliance. For conventional impressions, inspect the record before disinfecting and sending it. Check that the relevant teeth, preparation margins, sulcus, supporting tissues and anatomical landmarks have been captured. Look for pulls, bubbles, tray show-through, movement and areas where the material has detached from the tray. A common mistake is to recognise that an impression is not ideal but send it anyway because repeating it feels inconvenient. That inconvenience usually returns later as a poor fit, an adjustment, an additional appointment or a remake. The same principle applies to digital impressions. A scan can look clean and impressive on screen while still missing clinically important information. Digital does not automatically mean accurate. Whether analogue or digital, examine the record against the requirements of the restoration, not simply against whether the impression appears generally tidy. Give the technician a clear margin For fixed restorations, the technician must be able to identify the finish line consistently around the preparation. If the margin disappears subgingivally, is obscured by blood or saliva, or blends into an underprepared surface, the restoration design becomes uncertain. Good soft-tissue management and moisture control are therefore part of the laboratory workflow. Retraction should expose the relevant area without causing unnecessary trauma, and the impression or scan should show a continuous, readable margin. If you cannot confidently trace the margin yourself, the technician is unlikely to have better information. This does not mean every preparation must look identical. It means the boundary between prepared and unprepared tooth needs to be clear enough for the restoration to be designed accurately. Occlusion must be recorded, not assumed Many laboratory problems presented as fit issues are actually record problems. A restoration may seat on the model but require substantial occlusal adjustment because the bite record did not reproduce the patient’s true relationship. Before recording the bite, check that the patient is closing consistently and that the chosen material is appropriate. Avoid unnecessarily thick records that prevent repeatable closure. Make sure the opposing arch contains enough useful anatomy and that scans have been aligned correctly. For removable cases, the laboratory must understand the required vertical dimension, centre line, smile line, canine positions, lip support and occlusal plane where relevant. An old bite taken when the dental condition was completely different may not transfer usable information to the current situation. If teeth have been extracted or the occlusal stops have changed, consider whether a properly constructed bite block is required. The laboratory cannot safely reconstruct a new jaw relationship from an outdated record alone. Communicate aesthetic information objectively Shade selection is more than writing A3 on a docket. Shade guides, surgery lighting, surrounding teeth, dehydration and photography can all affect how colour is interpreted. For aesthetically demanding cases, photographs are extremely useful when taken consistently. Include an overall smile view, a retracted view and a close-up with the selected shade tab visible in the same plane as the teeth. Make sure the shade tab identification can be read. Also describe what matters. Is the adjacent tooth high in value? Is there cervical warmth, incisal translucency, mottling or a visible crack line that should be reproduced? Does the patient want the restoration to blend naturally, or are they requesting a lighter result? For anterior work, communicate the patient’s expectations before manufacture. “Natural” can mean different things to different people. A brief conversation recorded properly can prevent a subjective disagreement at the fit appointment. Use photographs for communication, not decoration Clinical photographs are valuable because they provide information that an impression cannot. They can show tooth position, facial symmetry, lip dynamics, surface texture, staining and how the existing dentition appears in context. Useful images should be focused, well lit and relevant to the question being asked. A distant photograph taken at an angle is unlikely to guide fine characterisation. Photographs are particularly helpful for:
A small, organised set of useful photographs is better than a large collection with no explanation. Tell the technician what each image is intended to demonstrate. Respect realistic laboratory timescales The due date should be based on when the case is clinically needed and what must happen in the laboratory, not simply the next available appointment in the diary. A laboratory case may need to be booked in, disinfected or digitally received, checked, designed, printed or cast, manufactured, finished, quality controlled, invoiced and delivered. Complex work may pass through several departments. An urgent case is not created merely by writing “urgent” on the prescription. If a shortened turnaround is necessary, contact the laboratory before promising the patient a fitting date. The team can then confirm whether the timescale is realistic and explain any compromises or additional requirements. Allow for collection, delivery, weekends and bank holidays. If the case needs an intermediate clinical stage, include time for the work to return to the laboratory and continue through production. Reliable planning protects the patient, the practice and the quality of the restoration. Respond quickly when the laboratory identifies a problem When a laboratory contacts you about an unclear margin, missing scan data or incomplete prescription, it is trying to prevent a downstream failure. A delayed response may cause the case to miss its production slot or delivery date. Make sure the laboratory knows the best route for urgent queries and that another appropriate team member can help when you are unavailable. When answering, address the actual question. If the technician asks whether to reduce an opposing cusp, accept a compromised material thickness or request a new preparation, “do what you think” does not resolve the clinical decision. Where possible, record the agreed instruction through the normal case communication channel. This keeps the decision traceable and prevents different members of the team working from conflicting messages. Learn from rejected records without becoming defensive Having an impression or scan rejected can feel frustrating, particularly during foundation training. However, a laboratory that flags an unusable record before manufacture is protecting you and your patient. Ask the technician to show you precisely what is missing. Compare the rejected record with an acceptable one and identify the clinical cause. The issue might be moisture, insufficient retraction, limited scanner access, tray selection, movement or an incomplete scan path. Useful questions include:
This turns a rejected case into practical training. The objective is not to avoid every future query. It is to improve the quality and consistency of the information you provide. Check the work properly when it returns Do not assume that laboratory quality control replaces clinical verification. The laboratory checks the work against the records and prescription it received. The dentist must assess it in the patient’s mouth. Before the appointment, confirm that the correct case and components have arrived. Review the prescription and inspect the work for obvious concerns. At the fit, follow an orderly sequence rather than adjusting several variables at once. For fixed work, this may include checking:
If something is wrong, record the issue clearly before making extensive adjustments. Photographs, fit-checking material and an accurate description help the laboratory determine whether correction or remanufacture is required. Handle remakes as an investigation A remake should not begin with an argument about blame. It should begin with evidence. The laboratory needs the original work, relevant models or files, a clear description of the problem and updated clinical records where necessary. “Does not fit” is less useful than identifying whether the restoration fails to seat, has an open margin, rocks, binds at a contact or differs from the current preparation. If the clinical situation has changed since the original records were taken, say so. Changes to the preparation, extractions, soft tissue, opposing dentition or bite can alter the basis on which the first appliance was made. A professional remake process asks three questions:
Build a relationship with the people making your work DFT dentists benefit enormously from speaking with technicians and, where possible, visiting the laboratory. Seeing how impressions, scans and prescriptions move through production makes the consequences of clinical decisions much clearer. Ask about the laboratory’s preferred scan workflow, photography protocol, turnaround times and requirements for different restorations. Find out who to contact for fixed, removable, implant and digital cases. At Bremadent, we believe that useful communication should happen before a problem reaches the fitting appointment. Our role is not simply to accept every case without question. It is to identify risks, explain the options and help the dental team make informed decisions. The strongest dentist-laboratory relationships are not built on never encountering a problem. They are built on communicating early, sharing responsibility and resolving problems consistently. A final checklist before sending the case Before submitting laboratory work, take one minute to confirm:
Working well with a laboratory is a skill that develops through repetition, feedback and curiosity. Learn what information technicians need, examine your own records critically and communicate before uncertainty becomes a manufactured problem. Those habits will save chairside time throughout your career and help you deliver more predictable care from the beginning. We provide a trusted laboratory service delivering consistent quality, saving chairside time, and supporting predictable patient outcomes. If you are a DFT or a newly qualified dentist, we can help, contact us today: 📞: 0208 520 8528 📧: [email protected] 📍: 25A St James Street, London, E17 7PJ
0 Comments
Your comment will be posted after it is approved.
Leave a Reply. |
Private Dental Laboratory in London
Kash Qureshi - Managing Director, Clinical Dental Technician
About the author:
Kash Qureshi is a Clinical Dental Technician (Denturist) in the U.K who oversees and quality controls over 3000+ fixed and removable prosthesis including implant cases from a clinical and technical aspect monthly at Bremadent Dental Laboratory & Swissedent Denture Clinic in London. www.swissedent.co.uk www.bremadent.co.uk [email protected] Categories
All
Archives
October 2026
|

RSS Feed