Digital impression systems can make restorative dentistry faster, cleaner and easier to communicate. They can also create false confidence. A colourful three-dimensional model on the screen may appear complete while hiding an unreadable margin, distorted bite or missing area that prevents accurate manufacture. For DFT dentists, the goal is not simply to complete a scan. It is to capture the clinical information the laboratory needs and verify it before pressing send. This guide explains how to produce usable intraoral scans, recognise common failure points and work with your laboratory when a digital record needs correcting. A successful scan starts before the scanner enters the mouth
An intraoral scanner records visible surfaces. It cannot see through blood or saliva, identify a finish line concealed by tissue or invent anatomy that has not been captured. Preparation design, soft-tissue management and moisture control therefore remain fundamental. Digital technology changes the method of recording the mouth, but it does not remove the clinical conditions required for an accurate impression. Before scanning, check that:
If the margin is not visible directly or through magnification, it is unlikely to become clearer inside the digital model. Understand what the laboratory receives The laboratory does not receive the live clinical situation. It receives a dataset representing the surfaces captured by the scanner, together with the prescription, bite relationship, photographs and any additional information you send. Technicians can rotate, enlarge and inspect the model. They can identify gaps, stitching errors, unclear margins and insufficient clearance. They cannot verify whether a digitally smooth area accurately represents the mouth if the scan was corrupted by movement, contamination or poor tissue control. The scanner software may also fill small areas automatically. This can make the model look visually complete even when the underlying data is weak. A polished image is not the same as a clinically reliable record. Judge the scan according to whether the critical anatomy has been captured accurately, not according to how impressive the model looks on screen. Follow a consistent scan path A systematic scanning path helps the software join images correctly and reduces the risk of missing surfaces. The precise technique varies between scanner systems, but consistency matters more than speed. For a full arch, maintain smooth movement, stable orientation and enough overlap for the software to recognise adjacent anatomy. Avoid repeatedly jumping between unrelated areas, as this can increase stitching difficulties. A practical sequence is to capture one continuous surface, move around the terminal tooth and return along the next surface before completing the remaining anatomy. Follow the manufacturer’s recommended protocol for your scanner. If tracking is lost, return to a clearly captured area with distinctive anatomy. Allow the software to relocate itself before continuing. Rapidly waving the scanner over an unrecognised area often creates more confusion. With experience, scanning becomes quicker. However, speed should result from a repeatable technique, not from omitting verification. Capture enough information around the preparation A beautifully scanned preparation is not sufficient if the adjacent teeth, contacts or surrounding tissues are incomplete. The laboratory needs the preparation in context. For fixed restorative cases, make sure the scan includes:
The correct amount of information depends on the case. A single posterior crown does not always require every millimetre of both arches, but the laboratory still needs stable anatomical reference points and sufficient information to evaluate contacts and occlusion. Make the margin genuinely readable An unclear margin is one of the most common reasons a digital case cannot proceed confidently. The finish line should be visible without the technician having to estimate where the preparation ends. Scan slightly beyond the margin so the software captures both the prepared surface and adjacent unprepared tooth structure. If tissue collapses immediately after retraction, organise the sequence so the preparation is scanned at the optimal moment. Some clinicians capture the opposing arch and bite first, then manage the tissue and scan the preparation last. The best sequence depends on the clinical situation and system. Where suitable, a two-cord or appropriate retraction technique may help expose the sulcus. Haemostasis must be achieved without leaving residue that contaminates the field. After scanning, enlarge the preparation and trace the finish line through 360 degrees. If any section disappears, rescan that area while the patient is still in the chair. Sending an unclear margin transfers a preventable clinical uncertainty into the manufacturing process. Control saliva, blood and reflective surfaces Moisture can interrupt data capture and reduce the definition of critical surfaces. Blood is particularly problematic around subgingival or equigingival margins because it occupies the very space that needs to be recorded. Use effective suction, isolation and four-handed dentistry where possible. Dry the field appropriately, but remember that soft tissues and prepared teeth can change if excessively dehydrated. Reflective surfaces, including metal restorations, scan bodies and highly polished areas, may also challenge some systems. Follow the scanner manufacturer’s instructions rather than routinely using unapproved powders or improvised techniques. If an area repeatedly fails to scan, stop and identify the cause. Continuing to pass the scanner over saliva, moving tissue or a contaminated lens usually produces a larger file, not better information. Good scanning is a controlled clinical procedure. The scanner performs best when the environment has been prepared for it. Inspect for stitching errors and distorted anatomy Intraoral scanners build a model by joining many images. If the software loses its position or receives repetitive, low-detail information, it can join sections incorrectly. Potential warning signs include:
If a localised error is identified, delete the affected data and rescan from a stable reference area. Avoid repeatedly scanning over corrupted information without removing it, as the software may continue building on the wrong foundation. Do not neglect the opposing arch The opposing scan determines the surfaces against which the restoration will be designed. Missing cusps, incisal edges or edentulous areas can limit the laboratory’s ability to assess the occlusion. Capture clean occlusal anatomy and enough buccal and lingual information for the model to remain stable. Where a removable appliance or larger restoration is planned, the laboratory may need more extensive supporting anatomy than it would for a straightforward single unit. Inspect the opposing arch with the same care as the preparation scan. A common workflow error is to spend several minutes refining the working arch and then rush through the opposing record. The restoration is designed within an occlusal system. Both sides of that system need to be represented accurately. Record the bite in a stable position Digital bite records are usually made by scanning the buccal surfaces while the patient closes. The software then aligns the arches using matching anatomy. Before scanning, ask the patient to close naturally and confirm the position. If they slide, posture or close differently each time, the digital relationship may not be reliable. Capture sufficient buccal anatomy on both arches and follow the scanner’s recommended number and location of bite scans. For larger cases, bilateral records may provide better verification. Once the arches are aligned, inspect the displayed contacts. Compare them with your clinical assessment. If the software shows widespread heavy contact on one side and no contact on the other when that was not observed clinically, repeat the bite. Do not rely solely on the software’s colour map. It is a useful aid, but it should be interpreted alongside the patient’s actual occlusion. Check restorative space before submission A scanner can help identify limited occlusal clearance, but the clinician still needs to decide whether the preparation and proposed material are suitable. Use the software’s clearance or reduction tools where available. Examine the entire preparation, including functional cusps and areas where the opposing tooth may create a localised restriction. If space is inadequate, the options might include modifying the preparation, reconsidering the restoration material, adjusting the opposing tooth where clinically justified or accepting a specific compromise. These are clinical decisions and should be resolved before manufacture where possible. If you intentionally accept limited space, tell the laboratory. Otherwise, the technician may pause the case, design outside ideal material parameters or be forced to make assumptions about your priorities. Complete the digital prescription properly Sending a scan file does not replace the laboratory prescription. The prescription explains what the dataset is for and communicates decisions that cannot be derived from surface anatomy. Include the restoration type, tooth notation, material, shade, stump shade where relevant and requested date. Explain any special requirements involving contacts, occlusion, emergence profile, pontic design, implant components or appearance. For implant cases, identify the implant system, platform, connection and components accurately. Confirm that the correct scan body was used and fully seated according to the relevant protocol. A digitally captured scan body does not help if the component itself was incorrect or incompletely seated. Attach relevant photographs and include a shade tab where aesthetic matching is important. The laboratory should not have to search through separate messages to reconstruct the prescription. Use the preview as your final quality-control stage Before pressing send, stop and examine the whole case. This is your opportunity to correct missing information while the patient is still present. A useful final check includes:
A disciplined 60-second review can prevent the inconvenience of recalling the patient for another scan. Know when to rescan and when to repeat Not every defect requires a complete new scan. One benefit of digital impressions is the ability to remove and recapture a localised area. A local rescan may be appropriate when a small area is missing, a section of margin was obscured or contamination affected a limited region. Delete enough surrounding data to give the software reliable reference points, then rescan using a controlled path. A full repeat may be safer when there is widespread distortion, an unreliable bite, substantial movement, incorrect patient records or uncertainty about the overall accuracy of the dataset. Do not keep repairing a fundamentally unreliable scan simply because restarting feels inefficient. The objective is not to preserve the first attempt. It is to submit a dependable clinical record. What happens when the laboratory cannot use the scan If the laboratory identifies a problem, the best response depends on the information missing. It may ask for a localised rescan, new bite, clearer photograph, amended prescription or complete repeat. At Bremadent, we want potential problems identified before they become restorations. A scan query should be treated as an opportunity to rescue the case, not as an obstacle created by the laboratory. When contacted, ask the technician or digital team to mark the affected area on an image where possible. This gives you a precise target and helps you understand how the defect appears at the design stage. Respond promptly, especially when a delivery date has already been agreed. Production cannot proceed safely while a critical clinical decision or missing record remains unresolved. Develop your technique through feedback Scanning improves quickly when feedback is specific. If several cases produce similar queries, look for the pattern. Repeatedly unclear distal margins may indicate limited scanner positioning. Incomplete posterior anatomy may relate to the scan path or patient access. Unstable bite alignments may point to insufficient buccal data or inconsistent closure. Ask the laboratory what it sees when opening your files. Technicians review scans from many clinicians and can often identify recurring weaknesses that are difficult to recognise from the surgery screen alone. A strong digital workflow is not defined by never receiving a query. It is defined by learning from the query and reducing the chance of the same issue recurring. Digital impressions are a team workflow Successful digital dentistry depends on more than owning a scanner. The dentist prepares and verifies the clinical situation, the nurse supports isolation and data handling, the software captures and transfers the record, and the laboratory evaluates and manufactures from it. When each stage is clear, digital impressions can reduce postage, improve communication and allow problems to be discussed quickly. When the workflow is rushed, the technology can simply deliver incomplete information faster. For DFT dentists, the most valuable habit is to treat every scan as a clinical record. Prepare the field carefully, follow a repeatable path, inspect the data critically and communicate the prescription properly. Pressing send should mean that you have checked the laboratory can see what it needs to see, understand what it needs to make and proceed without avoidable guesswork. We provide a trusted laboratory service delivering consistent quality, saving chairside time, and supporting predictable patient outcomes. 📞: 0208 520 8528 📧: [email protected] 📍: 25A St James Street, London, E17 7PJ
0 Comments
Your comment will be posted after it is approved.
Leave a Reply. |
Private Dental Laboratory in London
Kash Qureshi - Managing Director, Clinical Dental Technician
About the author:
Kash Qureshi is a Clinical Dental Technician (Denturist) in the U.K who oversees and quality controls over 3000+ fixed and removable prosthesis including implant cases from a clinical and technical aspect monthly at Bremadent Dental Laboratory & Swissedent Denture Clinic in London. www.swissedent.co.uk www.bremadent.co.uk [email protected] Categories